Application
1. Purposed:
a) For display only.
b) For control of system Hi-Lo setting values.
c) For analog or digital signal output. For central control or SCADA system
application.
2. Measured signals:
a) Voltage or Current.
b) AC or DC
3. Measuring range: For industrial system, the signal should very small such as mV, mA etc., and for power system purposed should be input V or A. The measuring display and output ranges are determined as required.
4. Input range: The meter input range can be accept from minimum mV to maximum V as required. Input can be accepted various and floating signal, and the terminals are all isolated from the external case, aux. power and input/output circuit.
5. Output range: AC&M has wide output range for available, various analogs 4~20mA or 1~5V etc., and RS-485 digital output.
a) For power system application, watthour and varhour has pulse output, based on the photo couple theory.
b) For Hi-Lo alarm setting functions, provide two SPDT setting points to trip or alarm the faulty system. The relay capacity has 120V, 5A continuous load.
c) For SCADA and central control systems, analog and digital output can be available, These meters combined with the traditional connection which has one display and one transducer separately.
6. Operation environment: The meter can be used under normal room temperature from -10’C to +55’C and relative humidity between 20 to 95 %.
AC Current (DMA)
Class 0.15% – Digital Ammeter
Ave Rms or True Rms Display
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
AC Voltage (DMV)
Class 0.15% – Digital Voltage Meter
Ave Rms or True Rms Display
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
AC Volt, Current & Frequency (DMVA)
Class 0.2% – 3 in one Digital Meters
Digital Voltmeter, Ammeter & Frequency Meter
Optional : Alarm Setting and Signal Output
Dual Aux. Power 110/220V AC
Reactive Power (DMQ)
Class 0.2% – Digital Var Meters
Single Phase or 3 Phases Watt Display
Bi-Directional
Optional : Signal Output
Dual Aux. Power 110/220V AC
Power Factor (DMPF)
Class 0.2% – Digital Cos θ Meters
Single Phase or 3 Phases
Optional : Signal Output
Dual Aux. Power 110/220V AC
Active Power (DMW)
Class 0.2% – Digital Watt Meters
Single Phase or 3 Phases Watt Display
Unit Direction or Bi-Directional
Optional : Signal Output
Dual Aux. Power 110/220V AC
Energy (DMWH)
Class 0.2% – Digital Energy Meters
Single Phase or 3 Phases
Unit Direction or Bi-Directional
Optional : Signal Output – Pulses, RS485 or Others
Dual Aux. Power 110/220V AC
Reactive Varhour (DMQH)
Class 0.2% – Digital Var-Hour Meters
Single Phase or 3 Phases
Bi-Directional
Optional : Signal Output
Dual Aux. Power 110/220V AC
Active Power & Energy (DMWWH)
Class 0.2% – Digital Watt & Watt-Hour Meters
Single Phase or 3 Phases
Unit Direction or Bi-Directional
Optional : Signal Output
Dual Aux. Power 110/220V AC
Reactive Power & Energy (DMQQH)
Class 0.2% – Digital Reactive Power & Energy Meters
Single Phase or 3 Phases
Bi-Directional
Optional : Signal Output
Dual Aux. Power 110/220V AC
Frequency (DMF)
Class 0.02% – Digital Frequency Meters
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
Multi-Power Meter (DMMP)
Class 0.2% – Digital Multifunction Power Meters
All in one at a glands
Display 3V,3A, 3W, W, Var, WH, VarH, PF, Hz, Harmonics
Optional : 4 Relay contact and 4 Signal Output
Dual Aux. Power 110/220V AC
Multi-Power Meter (DMPW)
Class 0.2% – Digital Multifunction Power Meters
Display 3V,3A, W, Var, WH, VarH, PF, Hz, Harmonics
Optional : Alarm and Signal Output
Dual Aux. Power 110/220V AC
DC Current Loop Rated (DMS)
Class 0.04% – Digital Display Meter
Wide Range of DC input Current – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
DC Voltage or Current Meter (DME)
Class 0.04% – Digital Display Meter
Wide Range of DC input Voltage or Current – Corresponding to the required
display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
Temperature RTD Meter (DMR)
Class 0.15% – Digital Temperature Meter
PT or CU input – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
Temperature & Controller Meter (DMTC)
Class + – 1 ° C – Digital Temperature Meters
3Wire PT input
Temperature display, Fan Operation, Alarm and skip
Optional : Signal Output & 3 Relay Contacts
Dual Aux. Power 110/220V AC
Thermocouple (DMT)
Class 0.15% – Digital Temperature Meters
Thermocouple Input: K, E, J, T, R, S, B… type
Optional : Signal Output & Relay Contacts
Dual Aux. Power 110/220V AC
Load Cell, Strain Gauge (DMB)
Class 0.1% – Digital Weight Meters
Optional : Signal Output & Relay Contacts
Dual Aux. Power 110/220V AC
RPM, Speed, Pulse (DMU)
Class 0.01% – Digital RPM, Speed, Pulse, Length, Fluid Meters
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
Potentiometer (DMP)
Class 0.1% – Digital Potentiometer, Level, Position Meters
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
Flow Meter (DML)
Class 0.2% – Digital Flow Meter
4~20mA input – Corresponding to the required display Range.
User Programmable
Optional : Relay contact, Signal Output and pulse output
Dual Aux. Power 110/220V AC
RS485 Meter (DMG)
Class 0.1% – Digital Modbus RTU Meter
RS485 Modbus RTU input – Corresponding to the required display Range.
User Programmable
Optional : 2 Relay contact and Signal Output
Dual Aux. Power 110/220V AC
Customized Requirement
If you have specific requirement on input, display, contact, signaling.
Our factory can customize to your specific need when provided details.