Power Transducers / Transmitters / Digital Meters

The interfacing experts on Automation, Control & Measurements. We provide full range of high precision instrument for your Power & Process Integration.

AC & M Power Transducer  

The AC&M Power Transducer accuracy for TD series is 0.2 class. Single Phase or 3 Phases Voltage or Current, Watt, Watt-Hour, Var, Var-Hour, Power Factor, and Frequency. It can directly output standard analog signal such as 4~20mA DC or 1~5V DC for V, A, W, Var, PF, F, or pulse signal for Watt-Hour and Var-Hour etc.. The Volts and Amps measurements includes True RMS. AC&M’s Power Transducer has impulse, surge and dielectric strength capabilities. The Power Transducer can be available for 1P2W, 1P3W, 3P3W 2 elements, 3P3W 3 elements, and 3A4W systems. Uni or Bi-directional power and energy flow measurement for Watt, Watt-Hour, Var, and Var-Hour. 

Central Control and SCADA Compatibility 

The TD and TS series Power Transducer providing as either a stand alone power monitoring station or as one element in large energy management network via analog signal to PLC, EMS, DCS and SCADA system applications. These Power Transducers are equipped with an optically isolated analog signal for measurement data. This allows the Power Transducer to be incorporated as one element within sophisticated SCADA or Energy Management Systems. The Power Transducer maintains communication compatibility with low cost PC-based power monitoring systems, Power View and SCADA systems. An IBM PC/486, or PC/586 compatible computer running Power View or SCADA software can be used to display the real-time measured data from TD or TS series Power Transducer. 

AC Voltage (TDV)

Class 0.2% – Single Phase or Three phases Transducer.
Ave Rms or True Rms 
Dual Aux. Power 110/220V AC
High Accuracy 0.2% RO at 23’C +/-5’C

AC Current (TDA)

Class 0.2% – Single Phase or Three phases Transducer. 
Avg Rms or True Rms 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C

Watt (TDW)

Class 0.2% – Single Phase or Three phases Current Measurement. 
Avg Rms or True Rms 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C

Var (TDQ)

Class 0.2% – Single Phase or Three phases Watt Measurement 
Unit or Bi-Directional 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 

Frequency (TDF)

Class 0.2% – Frequency Measurement 
Quartz Oscillator 
Measurement Range + – 10Hz or more 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 

Watt/Var (TDWQ)

Class 0.2% – Single Phase or Three phases Var Measurement 
Bi-Directional 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 

Power Factor (TDPF)

Class 0.2% – Single Phase or Three phases Watt & Var Measurement 
Single unit dual output Watt and Var 
Unit or Bi-Directional 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 

Watthour (TDWH)

Class 0.2% – Single Phase or Three phases Power Factor Measurement 
Bi-Directional 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 
Single unit dual output KWH and Watt 
Unit or Bi-Directional 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 

Var / Varhour (TDQQH)

Class 0.2% – Single Phase or Three phases Var & Var-Hour Measurement 
Single unit dual output VARH and VAR 
Bi-Directional 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 

Microprocessor Transducer (TRMT)

Class 0.2% – Combine Measurement 
Single unit Transducer – 3V,3A,W,Var, WH, VarH, PF and Hz 
Output: RS485 Modbus. 
Dual Aux. Power 110/220V AC 
High Accuracy 0.2% RO at 23°C +/-5°C 

Micro Processor Digital Meter  

The AC&M microprocessor digital panel meters are divided into two categories: one for power system application purposed, and the other is for industrial process measuring. For power system is an AC conversion to DC analog or RS-485 digital measure signal, application for Voltage, Current, Watt, Var, Watt-hour, Var-hour, Power Factor, and Frequency. For industrial process is a DC signal conversion to analog or digital signal such as DC-to-DC, temperature, load cell, speed, rotary, level etc.. These two kinds of digital meters have wide range applications and come in various types suitable to many application specifications, and independent isolating output. AC&M has designed a single input but combined with a digital display meter/transducer output and setting alarm function into one case, also provided high isolated ability for fault protection different from digital multi-meters in that they are used especially for single function, single range measurement. A wide range of equipment and analog to digital conversion in highly accurate digital measurement.

Recently, a digital meter combined with analog or digital output and two Hi-Lo setting relay is a trend of modern multi-function design concept. The traditional analog output has 4~20mA or 1~5V etc.. For more field useful purpose, RS-485 digital output is a necessary equipped. A digital meter relay consisting of a digital panel meter with a comparison function using digital switches has been developed. AC&M’s digital meters combined with unique display/switch relay and high isolated transducer together. Thereby enabling not only the reading of normal values, but also the comparison of large, medium and small values.

The meters have system output function that converts analog signals from sensors to digital signals for direct input to equipment such as computers, recorders computing unit to facilitate recording and automatic control.

AC&M can provide a number of digital panel meters to meet a wide range of applications through reliable design and reality control based on long experience with digital techniques. This is support by extensive and rigorous past production testing that is part of our quality-assurance control system using standards that are directly traceable to national standards. This quality assurance system is backed by an equally extensive and experienced after sales service.

Application

1. Purposed:
a) For display only.
b) For control of system Hi-Lo setting values.
c) For analog or digital signal output. For central control or SCADA system 
application.

2. Measured signals:
a) Voltage or Current.
b) AC or DC

3. Measuring range: For industrial system, the signal should very small such as mV, mA etc., and for power system purposed should be input V or A. The measuring display and output ranges are determined as required.

4. Input range: The meter input range can be accept from minimum mV to maximum V as required. Input can be accepted various and floating signal, and the terminals are all isolated from the external case, aux. power and input/output circuit.

5. Output range: AC&M has wide output range for available, various analogs 4~20mA or 1~5V etc., and RS-485 digital output.

a) For power system application, watthour and varhour has pulse output, based on the photo couple theory.
b) For Hi-Lo alarm setting functions, provide two SPDT setting points to trip or alarm the faulty system. The relay capacity has 120V, 5A continuous load.
c) For SCADA and central control systems, analog and digital output can be available, These meters combined with the traditional connection which has one display and one transducer separately.

6. Operation environment: The meter can be used under normal room temperature from -10’C to +55’C and relative humidity between 20 to 95 %.

AC Current (DMA)

Class 0.15% – Digital Ammeter 
Ave Rms or True Rms Display 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

AC Voltage (DMV)

Class 0.15% – Digital Voltage Meter 
Ave Rms or True Rms Display 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

AC Volt, Current & Frequency (DMVA)

Class 0.2% – 3 in one Digital Meters 
Digital Voltmeter, Ammeter & Frequency Meter 
Optional : Alarm Setting and Signal Output 
Dual Aux. Power 110/220V AC 

Reactive Power (DMQ)

Class 0.2% – Digital Var Meters 
Single Phase or 3 Phases Watt Display 
Bi-Directional 
Optional : Signal Output 
Dual Aux. Power 110/220V AC 

Power Factor (DMPF)

Class 0.2% – Digital Cos θ Meters 
Single Phase or 3 Phases 
Optional : Signal Output 
Dual Aux. Power 110/220V AC 

Active Power (DMW)

Class 0.2% – Digital Watt Meters 
Single Phase or 3 Phases Watt Display 
Unit Direction or Bi-Directional 
Optional : Signal Output 
Dual Aux. Power 110/220V AC 

Energy (DMWH)

Class 0.2% – Digital Energy Meters 
Single Phase or 3 Phases 
Unit Direction or Bi-Directional 
Optional : Signal Output – Pulses, RS485 or Others 
Dual Aux. Power 110/220V AC 

Reactive Varhour (DMQH)

Class 0.2% – Digital Var-Hour Meters 
Single Phase or 3 Phases 
Bi-Directional 
Optional : Signal Output 
Dual Aux. Power 110/220V AC

Active Power & Energy (DMWWH)

Class 0.2% – Digital Watt & Watt-Hour Meters 
Single Phase or 3 Phases 
Unit Direction or Bi-Directional 
Optional : Signal Output 
Dual Aux. Power 110/220V AC 

Reactive Power & Energy (DMQQH)

Class 0.2% – Digital Reactive Power & Energy Meters 
Single Phase or 3 Phases 
Bi-Directional 
Optional : Signal Output 
Dual Aux. Power 110/220V AC 

Frequency (DMF)

Class 0.02% – Digital Frequency Meters 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

Multi-Power Meter (DMMP)

Class 0.2% – Digital Multifunction Power Meters 
All in one at a glands 
Display 3V,3A, 3W, W, Var, WH, VarH, PF, Hz, Harmonics 
Optional : 4 Relay contact and 4 Signal Output 
Dual Aux. Power 110/220V AC 

Multi-Power Meter (DMPW)

Class 0.2% – Digital Multifunction Power Meters 
Display 3V,3A, W, Var, WH, VarH, PF, Hz, Harmonics 
Optional : Alarm and Signal Output 
Dual Aux. Power 110/220V AC 

DC Current Loop Rated (DMS)

Class 0.04% – Digital Display Meter 
Wide Range of DC input Current – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

DC Voltage or Current Meter (DME)

Class 0.04% – Digital Display Meter 
Wide Range of DC input Voltage or Current – Corresponding to the required 
display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

Temperature RTD Meter (DMR)

Class 0.15% – Digital Temperature Meter 
PT or CU input – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

Temperature & Controller Meter (DMTC)

Class + – 1 ° C – Digital Temperature Meters 
3Wire PT input 
Temperature display, Fan Operation, Alarm and skip 
Optional : Signal Output & 3 Relay Contacts 
Dual Aux. Power 110/220V AC

Thermocouple (DMT)

Class 0.15% – Digital Temperature Meters 
Thermocouple Input: K, E, J, T, R, S, B… type 
Optional : Signal Output & Relay Contacts 
Dual Aux. Power 110/220V AC 

Load Cell, Strain Gauge (DMB)

Class 0.1% – Digital Weight Meters 
Optional : Signal Output & Relay Contacts 
Dual Aux. Power 110/220V AC 

RPM, Speed, Pulse (DMU)

Class 0.01% – Digital RPM, Speed, Pulse, Length, Fluid Meters 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

Potentiometer (DMP)

Class 0.1% – Digital Potentiometer, Level, Position Meters 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

Flow Meter (DML)

Class 0.2% – Digital Flow Meter 
4~20mA input – Corresponding to the required display Range. 
User Programmable 
Optional : Relay contact, Signal Output and pulse output 
Dual Aux. Power 110/220V AC 

RS485 Meter (DMG)

Class 0.1% – Digital Modbus RTU Meter 
RS485 Modbus RTU input – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 110/220V AC 

Customized Requirement

If you have specific requirement on input, display, contact, signaling.
Our factory can customize to your specific need when provided details.

Isolating Transmitter  

The AC&M Industrial Transmitter is a high performance converter for many industrial allocations and high isolation requirement field. Many kinds of industrial producing machine or various electric signal needs to becoming a stable and accurate signal to display or counter etc.. AC&M has DC-DC, temperature, load cell/strain gauge, frequency-DC, DC-frequency, 2 wire current loop and pure DC power supply. Basically, no matter some kinds of transmitter need sensor and some unnecessary, AC&M’s transmitter has absolute transfer the input signal to an analog signal. It can directly output standard analog signal such as 4~20mA DC or 1~5V DC etc.. 

AC&M can provide a number of industrial transmitter to meet a wide range of applications through reliable design and reality control based on long experience with signal transfer techniques. This is support by extensive and rigorous past production testing that is part of our quality-assurance control system using standards that are directly traceable to national standards. This quality assurance system is backed by an equally extensive and experienced after sales service. 

Application 

1. Purposed 
a) For DC-DC signal isolating only. 
b) For dual or triple DC-DC signal output values. 
c) For many various small sensor signal to a standard analog output. 
d) For industrial control application. 

2. Measured signals 

a) Voltage or Current. 
b) AC or DC 

3. Measuring range :For industrial system, the signal should very small such as mV, mA etc., The measuring output ranges are determined as required. 

4. Input range :The meter input range can be accept from minimum mV to maximum V as required. Input can be accepted various and floating signal, and the terminals are all isolated from the bottom case, aux. power and input/output circuit. 

5. Output range: AC&M has wide output range for available, various analogs 4~20mA or 1~5V etc.. 

6. Operation environment: The meter can be used under normal room temperature from -5’C to +55’C and relative humidity between 20 to 95%.

DC Isolation (TWD)

Class 0.1% – DC Isolation OR Conversion Transmitter 
Single Input – Single Output 
Single Input – Dual Output 
Dual Aux. Power 85/265V AC/DC 

Current Loop (TWS)

Class 0.1% – Current Loop Isolation OR Conversion Transmitter 
Single Input – Single Output 
Single Input – Dual Output 
Input 4~20mA (2 Wire) 
Dual Aux. Power 85/265V AC/DC 

RTD Isolating (TWR)

Class 0.1% – RTD Isolation OR Conversion Transmitter 
Single Input – Single Output 
Single Input – Dual Output 
Input PT 100 (3 Wire) 
Dual Aux. Power 85/265V AC/DC 

Thermocouple (TWT)

Class 0.1% – Thermocouple Isolation OR Conversion Transmitter 
Single Input – Single Output 
Single Input – Dual Output 
Input K,E,J,T,R,S,B Type 
Dual Aux. Power 85V/265V AC/DC 

Frequency to DC (TWF)

Class 0.1% – Frequency to DC Isolation OR Conversion Transmitter 
Single Input – Single Output 
Single Input – Dual Output 
Input via Open Collector, Voltage Pulses, Contacts 
Dual Aux. Power 85V/265V AC/DC 

Potentiometer (TWP)

Class 0.1% – Potentiometer, Level, Position OR Conversion Transmitter 
Single Input – Single Output 
Single Input – Dual Output 
Input via 200 ~ 10K Ohms 
Dual Aux. Power 85V/265V AC/DC 

DC Alarm (TAD)

Class 0.1% – Digital Contact Meter with Isolation and Conversion Transmitter 
DC input – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 85V/265V AC/DC 

Current Loop (TAS)

Class 0.1% – Digital current Loop Meter with Isolation and Conversion Transmitter 
DC input via DC 4~20mA (2 Wire) 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 85V/265V AC/DC 

RTD (TAR)

Class 0.1% – Digital RTD Meter with Isolation and Conversion Transmitter 
Input PT100 (3 Wire) – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 85V/265V AC/DC 

Thermocouple (TAT)

Class 0.1% – Digital Thermocouple Meter with Isolation and Conversion Transmitter 
Input K,E,J,T,R,S,B type – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 85V/265V AC/DC 

Potentiometer (TAP)

Class 0.1% – Digital Potentiometr with Isolation and Conversion Transmitter 
Input 200 ~ 10K Ohms – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 85V/265V AC/DC 

Load Cell, Strain Gauge (TAB)

Class 0.1% – Digital Load cell, Strain Gauge Transmitter 
Input DC mV – Corresponding to the required display Range. 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 85V/265V AC/DC 

Calculas (TAA)

Class 0.1% – Digital Calculas Alarm Transmitter 
Input DC mV or mA. 
Function as an Adder, Subtractor, Multiplier etc 
User Programmable 
Optional : 2 Relay contact and Signal Output 
Dual Aux. Power 85V/265V AC/DC 

Customized

Customized Isolating Transmitter
If you have specific requirements for input, display, contact, signalling.
Our factory can customize to your specific need when provided details.